Refrigerator not cooling due to failed defrost heater
Why it happens here
In older refrigerators, the defrost heater and thermostat wear out and ice builds up on the evaporator coil, blocking airflow. The freezer stays cold but the fresh food section warms up. It is the single most common refrigeration call we get in Brooklyn Centre.
Our approach
We test the defrost heater and thermostat with a multimeter, confirm the failure, and replace both parts as a set. We also check the door gasket and the drain line while we are in there, because those often fail around the same time.